{"id":5177,"date":"2026-07-30T15:38:13","date_gmt":"2026-07-30T13:38:13","guid":{"rendered":"https:\/\/w3.ime-actia.de\/vehicle-diagnostics\/rp-1210\/"},"modified":"2026-08-13T10:09:04","modified_gmt":"2026-08-13T08:09:04","slug":"rp-1210","status":"publish","type":"page","link":"https:\/\/www.ime-actia.de\/en\/vehicle-diagnostics\/rp-1210\/","title":{"rendered":"RP 1210"},"content":{"rendered":"\n<div class=\"wp-block-essential-blocks-button root-eb-button-qyls3\"><div class=\"eb-parent-wrapper eb-parent-eb-button-qyls3 \"><div class=\"eb-button-wrapper eb-button-alignment eb-button-qyls3\"><div class=\"eb-button\"><div class=\"eb-button-inner-wrapper \"><a class=\"eb-button-anchor \" href=\"https:\/\/www.ime-actia.de\/en\/vehicle-diagnostics\/\" rel=\"noopener\"><i icon=\"fas fa-arrow-left\" class=\"fas fa-arrow-left eb-button-icon eb-button-icon-left hvr-icon\"><\/i>Back to Vehicle Diagnostics<\/a><\/div><\/div><\/div><\/div><\/div>\n\n<h2 class=\"wp-block-heading\" style=\"margin-top:var(--wp--preset--spacing--60)\">RP 1210<\/h2>\n\n<p class=\"wp-block-paragraph\"><strong>Brief introduction to RP1210<\/strong><\/p>\n\n<p class=\"wp-block-paragraph\">RP 1210 is a proven programming interface initiated through the &#8220;Recommended Engineering and Maintenance Practice&#8221; of the <a href=\"https:\/\/tmc.trucking.org\/\" target=\"_blank\" rel=\"noopener\">Technology &amp; Maintenance Council (TMC<\/a>) and the <a href=\"https:\/\/www.trucking.org\/\" target=\"_blank\" rel=\"noopener\">American Trucking Associations (ATA)<\/a>. This interface primarily enables access to vehicle communication interfaces (VCIs) in the truck sector. RP 1210 allows access to J1708\/J1587, CAN, J1939, and J1850 bus systems. Key use cases include programming, diagnostics, and analysis. Much like SAE J2534, the diagnostic interface can be used independently of the OEM\u2014a clear advantage for workshops.    <\/p>\n\n<h3 class=\"wp-block-heading\">Overview<\/h3>\n\n<p class=\"wp-block-paragraph\">The following diagram shows a simplified workflow of how an application uses RP1210:<\/p>\n\n<figure class=\"wp-block-image size-full\"><img loading=\"lazy\" decoding=\"async\" width=\"388\" height=\"464\" src=\"https:\/\/www.ime-actia.de\/wp-content\/uploads\/2026\/07\/image-19.png\" alt=\"Figure: Simplified process RP 1210\" class=\"wp-image-4687\" srcset=\"https:\/\/www.ime-actia.de\/wp-content\/uploads\/2026\/07\/image-19.png 388w, https:\/\/www.ime-actia.de\/wp-content\/uploads\/2026\/07\/image-19-251x300.png 251w\" sizes=\"auto, (max-width: 388px) 100vw, 388px\" \/><figcaption class=\"wp-element-caption\"><em>Simplified process RP 1210<\/em><\/figcaption><\/figure>\n\n<p class=\"wp-block-paragraph\"><br\/>RP1210_SendMessage transfers a byte buffer to the RP1210 library. The application is responsible for ensuring that the buffer content is in the format appropriate for the protocol. For ISO15765, for example, the format is as follows:<br\/>1 byte (Message Type) + 4 bytes (CAN ID) + 1 byte (Extended Address) + (0\u20134096) message bytes  <br\/> <br\/><strong>RP1210_ReadMessage<\/strong> returns a byte buffer, the format of which depends on the protocol. For ISO15765, the following information is added to the beginning of the buffer in addition to the format described above:<br\/>4 bytes (time stamp) + 0\/1 (echo) + 1 byte (indication status) <br\/> <br\/><strong>Echo<\/strong>: when enabled, indicates whether the client originally sent the message. If echo mode is disabled, this byte is not present. <br\/><strong>Indication Status<\/strong>: Message acknowledged, error occurred, first message of a segment (first frame of a multi-frame message).<\/p>\n\n<p class=\"wp-block-paragraph\">The API offers the following functions:<\/p>\n\n<figure class=\"wp-block-table is-style-stripes\"><table class=\"has-fixed-layout\"><thead><tr><th class=\"has-text-align-left\" data-align=\"left\">Function<\/th><th class=\"has-text-align-left\" data-align=\"left\">Description<\/th><\/tr><\/thead><tbody><tr><td class=\"has-text-align-left\" data-align=\"left\">RP1210_ClientConnect<\/td><td class=\"has-text-align-left\" data-align=\"left\">Establishing a logical connection to the RP 1210 DLL.<\/td><\/tr><tr><td class=\"has-text-align-left\" data-align=\"left\">RP1210_ClientDisconnect<\/td><td class=\"has-text-align-left\" data-align=\"left\">Terminating the logical connection to the RP 1210 DLL.<\/td><\/tr><tr><td class=\"has-text-align-left\" data-align=\"left\">RP1210_SendMessage<\/td><td class=\"has-text-align-left\" data-align=\"left\">Sends a message to the RP 1210 DLL.<\/td><\/tr><tr><td class=\"has-text-align-left\" data-align=\"left\">RP1210_ReadMessage<\/td><td class=\"has-text-align-left\" data-align=\"left\">Reads a message from the RP 1210 DLL.<\/td><\/tr><tr><td class=\"has-text-align-left\" data-align=\"left\">RP1210_SendCommand<\/td><td class=\"has-text-align-left\" data-align=\"left\">Sends a command to the RP 1210 DLL.<\/td><\/tr><tr><td class=\"has-text-align-left\" data-align=\"left\">RP1210_GetErrorMsg<\/td><td class=\"has-text-align-left\" data-align=\"left\">Translates an RP 1210 error code into text.<\/td><\/tr><tr><td class=\"has-text-align-left\" data-align=\"left\">RP1210_GetLastErrorMsg<\/td><td class=\"has-text-align-left\" data-align=\"left\">Translates an RP 1210 error code into a more detailed text.<\/td><\/tr><tr><td class=\"has-text-align-left\" data-align=\"left\">RP1210_GetHardwareStatus<\/td><td class=\"has-text-align-left\" data-align=\"left\">Returns the connection status.<\/td><\/tr><tr><td class=\"has-text-align-left\" data-align=\"left\">RP1210_ReadVersion<\/td><td class=\"has-text-align-left\" data-align=\"left\">Reads the version information of the RP 1210 API DLL via the API.<\/td><\/tr><tr><td class=\"has-text-align-left\" data-align=\"left\">RP1210_ReadDetailedVersion<\/td><td class=\"has-text-align-left\" data-align=\"left\">Reads the version information of the RP 1210 API DLL via the API (new preferred version).<\/td><\/tr><tr><td class=\"has-text-align-left\" data-align=\"left\">RP1210_Ioctl<\/td><td class=\"has-text-align-left\" data-align=\"left\">Used to change the status of vehicle communication. This was introduced in RP1210B and is currently used by RP1210 only for ISO9141 and KWP2000 communication. This function enables the future development of RP1210 to support additional automotive protocols.  <\/td><\/tr><\/tbody><\/table><figcaption class=\"wp-element-caption\"><em>RP1210 API Functions<\/em><\/figcaption><\/figure>\n\n<h3 class=\"wp-block-heading\">Features<\/h3>\n\n<ul class=\"wp-block-list\">\n<li>Multiple client applications can access the same vehicle bus in parallel.<\/li>\n\n\n\n<li>It is the task of the client application to assign the messages to the corresponding control units.<\/li>\n\n\n\n<li>Pure C API with 11 functions<\/li>\n\n\n\n<li>Error Handling by Evaluating Return Values (No Exceptions)<\/li>\n\n\n\n<li>Specified primarily for Windows<\/li>\n<\/ul>\n\n<p class=\"wp-block-paragraph\">Since RP 1210 is a relatively simple programming interface, a large part of the logic must be handled by the application itself.<\/p>\n\n<h3 class=\"wp-block-heading\">Integration into an Application<\/h3>\n\n<p class=\"wp-block-paragraph\">Every RP 1210 installation includes an .INI file and a .DLL file. The RP 1210 specification mandates the format for the filenames and their paths.<\/p>\n\n<figure class=\"wp-block-table is-style-stripes\"><table class=\"has-fixed-layout\"><thead><tr><th class=\"has-text-align-left\" data-align=\"left\">File type<\/th><th class=\"has-text-align-left\" data-align=\"left\">Installation path<\/th><th class=\"has-text-align-left\" data-align=\"left\">File name<\/th><\/tr><\/thead><tbody><tr><td class=\"has-text-align-left\" data-align=\"left\">INI<\/td><td class=\"has-text-align-left\" data-align=\"left\">GetSystemWindowsDirectory &#8211; WIN API<\/td><td class=\"has-text-align-left\" data-align=\"left\"><strong>VENDRX<\/strong>32.ini<\/td><\/tr><tr><td class=\"has-text-align-left\" data-align=\"left\">DLL<\/td><td class=\"has-text-align-left\" data-align=\"left\">GetSystemDirectory() &#8211; WIN API<\/td><td class=\"has-text-align-left\" data-align=\"left\"><strong>VENDRX<\/strong>32.dll<\/td><\/tr><\/tbody><\/table><figcaption class=\"wp-element-caption\"><em>RP1210 API Functions<\/em><\/figcaption><\/figure>\n\n<p class=\"wp-block-paragraph\"><strong>VENDRX<\/strong> is the manufacturer name of the interface.<\/p>\n\n<div class=\"wp-block-cover alignfull cta-footer\" style=\"margin-top:var(--wp--preset--spacing--80);margin-bottom:0;min-height:430px;aspect-ratio:unset;\"><span aria-hidden=\"true\" class=\"wp-block-cover__background has-ast-global-color-5-background-color has-background-dim-100 has-background-dim\"><\/span><div class=\"wp-block-cover__inner-container is-layout-constrained wp-container-core-cover-is-layout-15ae893d wp-block-cover-is-layout-constrained\">\n<div class=\"wp-block-columns is-layout-flex wp-container-core-columns-is-layout-2c464be3 wp-block-columns-is-layout-flex\">\n<div class=\"wp-block-column is-vertically-aligned-center is-layout-flow wp-block-column-is-layout-flow\" style=\"flex-basis:300px\">\n<figure class=\"wp-block-image aligncenter size-full has-custom-border\"><img loading=\"lazy\" decoding=\"async\" width=\"2000\" height=\"437\" src=\"https:\/\/www.ime-actia.de\/wp-content\/uploads\/2025\/11\/cropped-ACTIA_QUADRI_RVB.png\" alt=\"ACTIA logo\" class=\"wp-image-11\" style=\"border-radius:0px;box-shadow:none;object-fit:cover\" srcset=\"https:\/\/www.ime-actia.de\/wp-content\/uploads\/2025\/11\/cropped-ACTIA_QUADRI_RVB.png 2000w, https:\/\/www.ime-actia.de\/wp-content\/uploads\/2025\/11\/cropped-ACTIA_QUADRI_RVB-300x66.png 300w, https:\/\/www.ime-actia.de\/wp-content\/uploads\/2025\/11\/cropped-ACTIA_QUADRI_RVB-1024x224.png 1024w, https:\/\/www.ime-actia.de\/wp-content\/uploads\/2025\/11\/cropped-ACTIA_QUADRI_RVB-768x168.png 768w, https:\/\/www.ime-actia.de\/wp-content\/uploads\/2025\/11\/cropped-ACTIA_QUADRI_RVB-1536x336.png 1536w, https:\/\/www.ime-actia.de\/wp-content\/uploads\/2025\/11\/cropped-ACTIA_QUADRI_RVB-600x131.png 600w, https:\/\/www.ime-actia.de\/wp-content\/uploads\/2025\/11\/cropped-ACTIA_QUADRI_RVB-109x24.png 109w\" sizes=\"auto, (max-width: 2000px) 100vw, 2000px\" \/><\/figure>\n<\/div>\n\n\n\n<div class=\"wp-block-column is-layout-flow wp-block-column-is-layout-flow\" style=\"flex-basis:66.66%\">\n<h2 class=\"wp-block-heading has-ast-global-color-2-color has-text-color has-link-color wp-elements-1\">Do you have any questions about our products or services?<\/h2>\n\n\n\n<p class=\"has-ast-global-color-3-color has-text-color has-link-color wp-elements-2 wp-block-paragraph\"><strong>We are here for you! Send us your inquiry using the contact form \u2013 our team will get back to you as soon as possible. <\/strong><\/p>\n\n\n\n<div class=\"wp-block-buttons is-layout-flex wp-block-buttons-is-layout-flex\">\n<div class=\"wp-block-button\"><a class=\"wp-block-button__link wp-element-button\" href=\"https:\/\/www.ime-actia.de\/en\/contact\/\">Contact us<\/a><\/div>\n<\/div>\n<\/div>\n<\/div>\n<\/div><\/div>\n","protected":false},"excerpt":{"rendered":"<p>RP 1210 Brief introduction to RP1210 RP 1210 is a proven programming interface initiated through the &#8220;Recommended Engineering and Maintenance [&hellip;]<\/p>\n","protected":false},"author":1,"featured_media":0,"parent":2227,"menu_order":0,"comment_status":"closed","ping_status":"closed","template":"","meta":{"_eb_attr":"","site-sidebar-layout":"default","site-content-layout":"","ast-site-content-layout":"default","site-content-style":"default","site-sidebar-style":"default","ast-global-header-display":"","ast-banner-title-visibility":"","ast-main-header-display":"","ast-hfb-above-header-display":"","ast-hfb-below-header-display":"","ast-hfb-mobile-header-display":"","site-post-title":"disabled","ast-breadcrumbs-content":"","ast-featured-img":"","footer-sml-layout":"","ast-disable-related-posts":"","theme-transparent-header-meta":"","adv-header-id-meta":"","stick-header-meta":"","header-above-stick-meta":"","header-main-stick-meta":"","header-below-stick-meta":"","astra-migrate-meta-layouts":"default","ast-page-background-enabled":"default","ast-page-background-meta":{"desktop":{"background-color":"var(--ast-global-color-5)","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-opacity":"","overlay-gradient":""},"tablet":{"background-color":"","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-opacity":"","overlay-gradient":""},"mobile":{"background-color":"","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-opacity":"","overlay-gradient":""}},"ast-content-background-meta":{"desktop":{"background-color":"var(--ast-global-color-4)","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-opacity":"","overlay-gradient":""},"tablet":{"background-color":"var(--ast-global-color-4)","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-opacity":"","overlay-gradient":""},"mobile":{"background-color":"var(--ast-global-color-4)","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-opacity":"","overlay-gradient":""}},"footnotes":""},"class_list":["post-5177","page","type-page","status-publish","hentry"],"_links":{"self":[{"href":"https:\/\/www.ime-actia.de\/en\/wp-json\/wp\/v2\/pages\/5177","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/www.ime-actia.de\/en\/wp-json\/wp\/v2\/pages"}],"about":[{"href":"https:\/\/www.ime-actia.de\/en\/wp-json\/wp\/v2\/types\/page"}],"author":[{"embeddable":true,"href":"https:\/\/www.ime-actia.de\/en\/wp-json\/wp\/v2\/users\/1"}],"replies":[{"embeddable":true,"href":"https:\/\/www.ime-actia.de\/en\/wp-json\/wp\/v2\/comments?post=5177"}],"version-history":[{"count":1,"href":"https:\/\/www.ime-actia.de\/en\/wp-json\/wp\/v2\/pages\/5177\/revisions"}],"predecessor-version":[{"id":5178,"href":"https:\/\/www.ime-actia.de\/en\/wp-json\/wp\/v2\/pages\/5177\/revisions\/5178"}],"up":[{"embeddable":true,"href":"https:\/\/www.ime-actia.de\/en\/wp-json\/wp\/v2\/pages\/2227"}],"wp:attachment":[{"href":"https:\/\/www.ime-actia.de\/en\/wp-json\/wp\/v2\/media?parent=5177"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}